This guide covers the same PC 2.0.77 base game as the existing railway guide, without Space Age or mods. The Factorio Wiki's pump history records changes in 2.1.7 to connection ends and connections to curved or misaligned wagons. This guide therefore assumes a straight, aligned wagon stopped at a station in 2.0; do not carry these placement conditions over to 2.1.
Fluid wagon research and materials for one wagon
After researching Railway and Fluid handling, research Fluid wagon. In the 2.0.77 research data, it costs 200 red and 200 green science packs, with 30 seconds per research unit. That is not a promise of actual completion time, which also varies with the number and speed of labs.
| Item | Ingredients for one | Suggested amount for the first setup |
|---|---|---|
| Fluid wagon | 10 iron gear wheels, 16 steel plates, 8 pipes, and 1 storage tank | 1 wagon |
| Pump | 1 engine unit, 1 steel plate, and 1 pipe | 1 for loading + 1 for unloading |
| Storage tank | 20 iron plates and 5 steel plates | One receiver at each station is a suggested setup |
The table lists ingredients for the completed items. The storage tank consumed to make the wagon is separate from the tanks used at the stations. Make engine units in an assembling machine. Pumps and storage tanks are unlocked by Fluid handling.
For a first setup, consider replacing the cargo wagon in A One-Train Shuttle Railway with one fluid wagon. Prepare two locomotives facing outward at opposite ends, fuel, a separate single-track line with two stations, pipes, and power poles at both stations. Check the railway guide for signals, station orientation, and the return route.
Start with one fluid—crude oil—and one pump at each station
The loading side follows this route: “oil well → pipe → loading tank → pump → fluid wagon.” The unloading side is “fluid wagon → pump → unloading tank → refinery.” These are flow examples, not a tested layout with measured distances or stopping positions.
A fluid wagon carries one fluid type. For the first run, use an empty wagon and crude-oil-only pipes; do not connect water or petroleum gas to the same system. A normal-quality wagon in 2.0 has a capacity of 50,000, but you do not need to wait for a full load on the first test.
Use the electric “Pump” for loading and unloading. Do not confuse it with the “Offshore pump” that draws water at a shore or the “Pumpjack” that extracts crude oil. For a station pump to work, fluid must be available, the output must have room, power must be present, and the connection must be correct.
Stop at the station, then align the pump
- Give the two stations distinct names, such as “Crude - Load” and “Crude - Unload,” and add them as destinations in the train schedule.
- Provide a straight section long enough for the entire fluid wagon, then use automatic mode to bring the fueled train to the station. Do not use an arbitrary manual stopping position as the alignment reference.
- Place the pump beside the stopped fluid wagon. Do not align it along the track: one end must face the wagon and the other the pipes. Make sure you are not beside a locomotive instead.
- For loading, orient flow from the tank to the wagon; for unloading, from the wagon to the tank. Connect pipes to the pump's front and back, not its sides, and place it within a power pole's coverage.
- Check that the pump head reaches the tank on top of the wagon. If it does not connect, review the wagon's stopping position, straight track, orientation, and power. After it connects, check the crude-oil amounts in both wagon and tanks.
In 2.0 the wagon must align correctly to the rail grid; pumps do not work with wagons on curves or at an angle. Before adding more pumps, verify one connection to a single wagon that has arrived correctly at the station. If circuit conditions or a fluid filter are set on the pump, also confirm that crude oil is allowed.
Set the train to manual or stopped while changing the layout, and move clear of the track before resuming. These steps organize checks from the cited references; they are not a verified in-game run or a reproduction of every layout.
Test one round trip with a partial load and an empty wagon
For the first test, one option is to set the loading station to “Time passed: 30 seconds” and the unloading station to “Cargo empty.” Thirty seconds is a test setting, not a guarantee that the wagon will fill. Check whether the crude-oil amount increases during loading; if it does not, fix loading before repeating the route.
At the unloading station, confirm that the wagon's crude oil decreases and the unloading tank's amount increases. If the receiving tank is full, the wagon will not become empty and the train will keep waiting. Make room at the destination, for example by sending fluid to the refinery, before resuming.
After one successful loop, change loading to “Full cargo” or adjust the wait time to match supply. If the train should depart on either full cargo or elapsed time, connect the conditions with OR. This guide has not measured a guaranteed loading time for one pump or how many wagons meet a factory's demand.
Separate connection, flow, and train problems
| Situation | Check | Next action |
|---|---|---|
| Pump head does not reach the wagon | Arrival at station, wagon position, straight track, pump direction, power | Stop automatically at the station and realign beside the wagon |
| Connected, but will not load | Crude oil in loading tank, pipes, pump arrow, conditions, and filter | Confirm crude oil reaches the pump and can be sent to the wagon |
| Connected, but will not unload | Unloading direction, room in receiver, fluid type | Make room in a crude-oil-only receiver and follow the flow to the refinery |
| Train does not leave loading station | Full-load wait and insufficient supply | Check the test's time condition and the amount actually loaded |
| Train does not leave unloading station | “Cargo empty” wait and a full tank | Clear the blockage at the unloading destination before removing the wait condition |
| “No path” or “Destination full” | Station orientation, locomotives, route, station limit | See Railway diagnostics by message |
Once crude oil reaches the factory, continue to Making Blue Science from a Refinery. If outputs from Advanced oil processing are blocked, see Heavy- and Light-oil Cracking and Excess Output Control. Before adding a second train or joining other routes, see A Two-Train One-Way Loop with Track Directions and Signals.
For storage-tank ingredients and connections, see How to Make and Use a Storage Tank.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.