Scope: PC full release 1.2 series, standard power consumption, 100% clock speed, normal Coal, no mods. This covers a first setup with one generator near a water source.
Unlock Coal Power after your first Space Elevator delivery
Tier 3 unlocks after the first Space Elevator delivery. Completing the HUB alone does not unlock the Coal Power Milestone.
- Complete the first Space Elevator delivery.
- Select “Coal Power” in Tier 3 at the HUB Terminal.
- Submit 150 Reinforced Iron Plates, 50 Rotors, and 500 Cable.
- Complete the launch action at the terminal.
- Check that Coal Generators, Water Extractors, and Pipelines are available in the build list.
This unlock also makes Coal available to the Resource Scanner. Look for a water source near a Coal node, not just the node itself, so you have a place for a Water Extractor.
Prepare one generator’s worth near water
For your first setup, avoid pumping water to a high plateau. Place the generator near water so the pipeline can stay short. A Water Extractor needs sufficient water depth; if you cannot place it in shallow water, check a slightly deeper spot.
| Equipment | Role and building materials |
|---|---|
| 1 Coal Generator | 20 Reinforced Iron Plates, 10 Rotors, 30 Cable |
| 1 Water Extractor | 20 Copper Sheets, 10 Reinforced Iron Plates, 10 Rotors |
| Miner Mk.1 on a Coal node | Sends Coal onto a belt |
| Belts, Pipelines, Power Poles, and Power Lines | Connect Coal, water, and power separately |
| Fueled Biomass Burner | Startup power for mining and pumping |
The water machine here is a Water Extractor placed on the water, not a Pipeline Pump attached along a pipe. A Pipeline Pump alone cannot draw water from a source.
Building a Miner and connecting a belt follows the same idea as your first automated iron smelting line, but place it on a Coal node.
Connect Coal with a belt and water with a pipeline
- Build a Miner Mk.1 on a Coal node.
- Connect a belt from the Miner’s output to the Coal input on the generator.
- Place a Water Extractor at a water source.
- Connect a Pipeline from the Water Extractor’s outlet to the generator’s water input.
- Run Power Lines from a Power Pole to the Miner and Water Extractor.
- Connect the Coal Generator to the same power grid.
The Coal Generator has a solid-fuel input and a water input. Coal arriving does not mean water has arrived too.
A Water Extractor has a default head lift of 10 m. Even with a supply rate of 120 m³/min, it cannot push water to any height you choose. For the first startup, use a low, short pipeline. To reach a factory on high ground, extend the power line from the Coal power setup instead; this avoids adding a water-side problem.
Use Biomass power to start mining and pumping first
Before the Coal Generator is generating, there is no power from it for the Miner and Water Extractor. Use Biomass power for startup.
- Make a separate power grid for only the Miner, Water Extractor, and generator; do not connect the whole factory yet.
- Connect an independent Biomass Burner loaded with fuel to that grid.
- Wait for the Miner to send Coal and the Water Extractor to send water.
- Check the Coal Generator screen for both Coal and water.
- Once generation begins, watch that Coal and water keep arriving without interruption.
- Check capacity and consumption in the power graph, then connect the factory only within the available margin.
A Miner Mk.1 uses 5 MW and a Water Extractor uses 20 MW, so startup for these two machines requires 25 MW. With no other loads, this fits within the 30 MW capacity of one standalone Biomass Burner. Do not confuse it with the single 20 MW burner attached to the HUB.
Connecting the whole factory at the start adds its other power consumption to the 25 MW. Rather than repeatedly tripping the breaker while trying to recover, start only the supply side first.
You cannot use all 75 MW for the factory
One standard Coal Generator produces 75 MW using 15 Coal/min and 45 m³/min of water. One Water Extractor supplies 120 m³/min, which is within capacity for this single generator.
However, the machines extracting water and mining Coal also consume power. Allowing for their normal operation in this setup, 75−20−5=50 MW is a guide to what remains for other equipment. Subtract any additional pumps or other loads too.
This is a one-generator setup for confirming the first startup. For a larger plant, recalculate the Coal supply, water supply, pipeline flow, and startup power rather than just adding more generators.
If it will not start or stops after a while
| State | What to check |
|---|---|
| Coal accumulates but no power is generated | Is a Pipeline connected to the generator’s water input, and is water arriving? |
| The Water Extractor stays off | Startup power, power connection, and standby state |
| Water is at the extractor but not the generator | Pipeline gaps, elevation, and the connection at the generator |
| It runs for a while, then stops | Has the generator used up its internal stock because Coal or water supply is not keeping up? |
| The grid trips when you connect the factory | Is total consumption above capacity, including the power equipment itself? |
Keep the startup Burner until both water and Coal are stable. Prepare Solid Biofuel too, so you can restart the support equipment if it stops.
If a breaker trips, fix supply or load first, then restart from the power screen. If it runs only just after you add fuel by hand, check whether automatic delivery continues.
Once generation is stable and you want to speed up production, see Unlocking overclocking in the MAM and checking conveyor limits. Recheck power consumption after changing settings.
When you have spare generation, unlock and charge Power Storage, then check its charge level to prepare for temporary power shortages.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.