A medium electric pole at normal quality supplies machines within a 7×7-tile area, while the wire reach between poles is 9 tiles. These are separate conditions. If a nearby machine does not run, check the blue supply area and then trace the wire back to the power source.

Finish the research and prepare Copper Cable, not Copper Plates

Scope: PC 2.0.77, base game, normal quality, no Space Age or mods. This covers a first placement extending from Small Electric Poles to Medium Electric Poles and checks why a machine may not receive power. Comparing all quality levels and designing circuit wiring are out of scope.

Confirm that “Electric energy distribution 1” is complete in the research screen. It requires Steel Processing and Logistic Science Pack research. Having the materials does not let you craft a recipe that has not been researched.

Materials for 1 Medium Electric PoleQuantity
Iron Stick4
Steel Plate2
Copper Cable2

In version 2.0.77, the material is Copper Cable. Keep this separate from older explanations that use Copper Plates. Iron Sticks and Steel Plates also cannot be replaced by having Iron Plates alone. The suggested first step is to craft a few, connect them to an existing power plant, and check that they work before scaling up.

If your green science production has stopped, first return to Making and feeding Green Science Packs to labs.

Put the machine inside the blue 7×7 supply area

  1. Hold the Medium Electric Pole on your cursor and position it near the machine you want to power.
  2. Look at the blue supply area shown on screen.
  3. Find a position where the target machine is within the area and is highlighted as a connection target.
  4. Place the pole.
  5. Check the machine’s power indicator and operating state.

A building connects when at least one of its tiles is inside the supply area. Use the on-screen highlight to check the target instead of trying to surround the entire building. If you also want to power a nearby Inserter or another machine, each one needs to be in a supply area too.

Do not assume that “the wire reaches 9 tiles, so a machine 9 tiles away will run.” Nine tiles is the pole-to-pole wire condition; the blue area that supplies machines is 7×7. For a machine farther away, add a pole nearby and connect that pole to the power network.

Trace the actual wire back to the power plant

The normal-quality wire reach between Medium Electric Poles is 9 tiles. When connecting different pole types, the shorter reach also constrains the connection. Replacing only one side with a Medium Electric Pole does not guarantee that it will connect to a pole farther away than before.

  1. Check whether a wire is visible from the new pole to an existing pole.
  2. If not, try placing it closer to the other pole.
  3. Once connected, follow the next poles and wires back to the power plant.
  4. Check that the power-generating buildings are inside a nearby pole’s supply area too.
  5. Open a pole on the factory side and check the state of its power network.

A pole placed normally nearby connects automatically to poles it can reach, but appearance alone does not confirm a connection. After using a special placement key or manual wiring, inspect the wire that is actually shown. For this first check, the suggested approach is to avoid adding disconnection actions and test a small layout with normal placement.

A pole’s screen shows information about the power network it belongs to. A power plant in another location does not supply a disconnected factory. Compare the plant and factory sides and confirm that they belong to the same network.

Adding poles does not increase generation capacity

StateWhat to check next
Cannot craft a Medium Electric PoleElectric Energy Distribution 1 research, plus Iron Sticks, Steel Plates, and Copper Cables
Only some machines have no powerWhether each machine and nearby Inserters are inside a blue supply area
A machine inside the area still has no powerThe wire back to the power plant and whether the network is disconnected
Poles do not connect to each otherBoth pole types, the distance, and the actual wire connection
Everything slows down and demand is not metGeneration capacity on the same network, plus water, fuel, and steam supply
Generation is low but the factory runs normallyWhether demand is being met; do not add generation based only on a low output figure

Poles deliver electricity; they do not generate it. If the network is connected but cannot meet demand, see Checking water, fuel, steam, and output for steam power. Do not keep adding poles without checking generation.

If only the lighting seems wrong, see Lamp power and day/night lighting. Deliberately switching power off is a separate use case covered by Wiring a power switch.

Sources and scope of verification

The developer’s fixed 2.0.77 recipe.lua and technology.lua were checked for the Medium Electric Pole’s ingredients and research prerequisites. The community-edited official Factorio Wiki’s “Medium electric pole” was checked for the normal-quality 7×7 supply area, 9-tile wire reach, and the change to Copper Cable in 2.0.7. “Electric system” was checked for the blue supply area, building connection, and per-network displays. Its obsolete five-connection limit was not used. All quality levels, optimal pole spacing, circuit designs, every patch, and in-game behavior are unverified. The small-layout tracing procedure is an editorial suggestion.

Sources and references

Questions and contributions

Share questions, corrections or play reports. Only approved posts for this article and language appear here.

Submit for review

Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.