A Power switch connects or disconnects the copper wire on its two sides. If machines still run while it is off, check for another wire path that bypasses the switch. Start with a small branch serving one machine!

Scope: PC 2.0 series, base game, normal quality, no mods. This guide covers manual on/off switching and wiring. It does not set up a circuit that automatically starts backup generation based on accumulator charge.

Wiring paths to use and avoid

WiringWhat happens when switched offCheck
Main-power pole → switch → equipment-side poleThe connection between the two sides is cutConnect the contacts to the correct, separate sides
A separate copper wire directly joins the two polesThe other path remains connectedRemove the direct connection and route power through the switch
Another generator is on the equipment sideIt can supply power from that sideCheck every power source in the area you want to stop
A charged accumulator is on the equipment sideIt can provide its stored energyDo not equate disconnecting the grid with an immediate stop

The switch itself needs no power and does not limit the maximum power passing through it. For an insufficient-generation problem, go back to Steam power and checking an electricity shortage.

Six steps to test a small branch

  1. Choose one machine to stop. Check a small area before switching off an entire defense line or factory.
  2. Separate the main-power and equipment sides. Check the poles and copper wires between them. Also check for an independent generator or accumulator on the equipment side.
  3. Place the switch between the two sides. Check the connection points on screen. Placing the switch does not remove an existing direct connection by itself.
  4. Connect each side with the copper wire tool. Open the tool with Alt+C or select it from the shortcut bar, then left-click the poles and switch contacts to connect them.
  5. Remove any direct connection that bypasses the switch. Use the copper wire tool to select the existing connection and cut the unwanted wire. Take care not to cut another branch from the main supply.
  6. Toggle the switch and check the result. Open the switch, toggle it, and watch the equipment-side power indicator and machine. Restore the state you need when finished.

Starting with a small area is an editorial suggestion. Set up a single path from the main supply through the switch to the equipment side; if power still reaches the equipment while off, look for another path. After adding poles, check again for any other copper-wire connections.

Using the 2.0 copper wire tool

ActionDefault PC inputNote
Open the copper wire toolAlt+CYou can also select it from the shortcut bar
Connect poles and switches / remove a wireWith the tool, left-click both endpointsCheck the endpoints and which side of the switch they are on
Return to the cursorQEnds the wiring operation
Another way to remove wires from a poleShift + left-clickThis removes wires broadly from the selected pole; distinguish it from changing just one wire here

From 2.0.7 onward, the wire used for wiring is separate from Copper cable, an intermediate material, and is not consumed when connecting or disconnecting. Do not confuse this with a process that requires crafting material for every wire connection. Copper cable as a material and the Copper wire connection tool have different uses.

What to check if machines still run while off

SituationCheck first
Power still reaches equipment while offAnother copper-wire path between the sides, another power source, or an accumulator
No power reaches equipment while onThe contacts on both sides, the poles, and the connection to the main supply
Other machines stopped tooWhether the wire you removed was shared with a branch that still needs power
Power behaves unexpectedly after rewiringCheck the electricity screen and look again for another path

You can also open and toggle the switch from the map. Before operating it from a distance, check on site which area it disconnects. For accumulator behavior, see Preparing solar power for the night. A successful manual toggle does not mean an automatic backup-power circuit is in place.

Sources and references

Questions and contributions

Share questions, corrections or play reports. Only approved posts for this article and language appear here.

Submit for review

Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.