A Power switch connects or disconnects the copper wire on its two sides. If machines still run while it is off, check for another wire path that bypasses the switch. Start with a small branch serving one machine!
Scope: PC 2.0 series, base game, normal quality, no mods. This guide covers manual on/off switching and wiring. It does not set up a circuit that automatically starts backup generation based on accumulator charge.
Wiring paths to use and avoid
| Wiring | What happens when switched off | Check |
|---|---|---|
| Main-power pole → switch → equipment-side pole | The connection between the two sides is cut | Connect the contacts to the correct, separate sides |
| A separate copper wire directly joins the two poles | The other path remains connected | Remove the direct connection and route power through the switch |
| Another generator is on the equipment side | It can supply power from that side | Check every power source in the area you want to stop |
| A charged accumulator is on the equipment side | It can provide its stored energy | Do not equate disconnecting the grid with an immediate stop |
The switch itself needs no power and does not limit the maximum power passing through it. For an insufficient-generation problem, go back to Steam power and checking an electricity shortage.
Six steps to test a small branch
- Choose one machine to stop. Check a small area before switching off an entire defense line or factory.
- Separate the main-power and equipment sides. Check the poles and copper wires between them. Also check for an independent generator or accumulator on the equipment side.
- Place the switch between the two sides. Check the connection points on screen. Placing the switch does not remove an existing direct connection by itself.
- Connect each side with the copper wire tool. Open the tool with Alt+C or select it from the shortcut bar, then left-click the poles and switch contacts to connect them.
- Remove any direct connection that bypasses the switch. Use the copper wire tool to select the existing connection and cut the unwanted wire. Take care not to cut another branch from the main supply.
- Toggle the switch and check the result. Open the switch, toggle it, and watch the equipment-side power indicator and machine. Restore the state you need when finished.
Starting with a small area is an editorial suggestion. Set up a single path from the main supply through the switch to the equipment side; if power still reaches the equipment while off, look for another path. After adding poles, check again for any other copper-wire connections.
Using the 2.0 copper wire tool
| Action | Default PC input | Note |
|---|---|---|
| Open the copper wire tool | Alt+C | You can also select it from the shortcut bar |
| Connect poles and switches / remove a wire | With the tool, left-click both endpoints | Check the endpoints and which side of the switch they are on |
| Return to the cursor | Q | Ends the wiring operation |
| Another way to remove wires from a pole | Shift + left-click | This removes wires broadly from the selected pole; distinguish it from changing just one wire here |
From 2.0.7 onward, the wire used for wiring is separate from Copper cable, an intermediate material, and is not consumed when connecting or disconnecting. Do not confuse this with a process that requires crafting material for every wire connection. Copper cable as a material and the Copper wire connection tool have different uses.
What to check if machines still run while off
| Situation | Check first |
|---|---|
| Power still reaches equipment while off | Another copper-wire path between the sides, another power source, or an accumulator |
| No power reaches equipment while on | The contacts on both sides, the poles, and the connection to the main supply |
| Other machines stopped too | Whether the wire you removed was shared with a branch that still needs power |
| Power behaves unexpectedly after rewiring | Check the electricity screen and look again for another path |
You can also open and toggle the switch from the map. Before operating it from a distance, check on site which area it disconnects. For accumulator behavior, see Preparing solar power for the night. A successful manual toggle does not mean an automatic backup-power circuit is in place.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.