This guide covers PC 1.2 with standard costs and no mods. Sources were checked on October 20, 2026; this is not an in-game test. The example uses liquid water. Gases follow different head-lift rules, so do not apply that explanation unchanged to them.
Check capacity and construction costs
| Building / Capacity | Unlock | Build cost |
|---|---|---|
| Fluid Buffer (400m³) | Tier 3 · Coal Power | 10 Copper Sheets, 5 Modular Frames |
| Industrial Fluid Buffer (2400m³) | Tier 5 · Petroleum Power | 5 Encased Industrial Beams, 10 Copper Sheets, 25 Plastic |
The industrial version holds 6 times as much. Unlocks, pipes, pumps and foundations cost extra. A buffer holds only 1 fluid type at a time. Its two connectors are bidirectional, not fixed one-way input and output ports.
Fill with water and watch the stored amount
- Prepare the water supply Connect a working Water Extractor to the buffer with a short pipe. Start with little elevation difference.
- Check the amount Open the buffer and watch the water increase. Leaving the other connector unused initially isolates the supply side.
- Connect a consumer Run a pipe from the other connector to a water-consuming building. For your first power station, see setting up coal power.
- Watch it during operation If use exceeds supply, the reserve also shrinks. Reaching full once does not prove the ongoing supply is sufficient.
Storage capacity is different from throughput per minute. Mk.1 pipes carry at most 300m³/min. Adding a larger buffer increases neither this limit nor water production.
Check elevation when the buffer will not fill
Water level affects head lift. A full standard buffer has 8m of head lift from the center of its pipe connector; the industrial version has 12m. Partial filling means less head lift. Do not assume an empty buffer passes upstream head lift straight through.
If water stops at a certain height, check supply and consumption, then follow pipeline head-lift and pump checks. Many buffers in series take time to start up, so learn the behavior with 1 first.
Check the scope before flushing
| Situation or action | Meaning and check |
|---|---|
| Stored amount keeps falling | Check insufficient or interrupted supply and consumption; extra capacity alone cannot fix it |
| This Buffer Only | Deletes fluid inside the selected buffer |
| Full Pipe Network | Also deletes fluid in connected pipes and buffers |
Flushing deletes rather than retrieves fluid. Even when switching fluids, stop the supply route first and check what will be emptied. If water is simply running low, do not empty the whole network before diagnosing why.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.