Yield is different from a stopped machine
For PC 2.1.23, normal quality, no mods, Nauvis crude oil; Space Age is not required. This starts after oil extraction is working. For initial placement and refining, use the first oil and blue science guide (Japanese).
Each resource spot accepts one pumpjack at a fixed position. Unmodified output is its yield fraction × 10 fluid/second: 100% means 10/s, 60% means 6/s. Read one spot's yield, not a cluster total. Modules and mining productivity change actual output.
Yield loses one percentage point every 300 extraction cycles. A cycle takes one second without speed changes, but pauses and modifiers prevent a fixed real-time depletion deadline.
Check before expanding
- Open the affected pumpjack, inspect its status and modules, and read the resource spot's current yield. Distinguish continuous low output from a complete stop.
- Check power coverage and available supply, then any circuit condition disabling the pumpjack. Normal base consumption is 90 kW; speed modules increase the power burden.
- Follow the outlet through pipes, tanks and refineries. A full downstream system prevents delivery regardless of resource yield. Check product congestion using oil cracking and overflow (Japanese).
- Restore downstream oil consumption, then compare supply against current yield. A single tank-level snapshot does not prove exhaustion.
- For a running low-yield pumpjack, consider already unlocked speed modules. It has two slots; two normal-quality Speed module 3 modules turn an unmodified 2/s example into 4/s. Secure the required research, manufacturing and extra electricity first.
- If consumption still exceeds supply, survey another oil field and prepare transport and defenses before connecting it. Existing low-yield wells can keep operating; demolition is not required.
The floor uses the original yield
| Known initial yield | Unmodified initial output | Unmodified floor |
|---|---|---|
| 100% | 10/s | 2/s |
| 300% | 30/s | 6/s |
The floor is the larger of 20% of initial output and 2/s. Not every field ends at 2/s. A current 300% reading does not establish a 6/s floor unless 300% was its original yield. The table is a calculation for known initial values.
For zero output, check electricity, circuits and blocked outlets first. If placement fails, use the fixed crude-oil resource position rather than ordinary ground. Offshore pumps and pipe pumps cannot replace a pumpjack.
Limits when adding speed
Keep quality, research and other speed bonuses consistent when comparing modules. The 2→4 example is conditional, not a measured guarantee for your whole factory. Speed cannot cure an electricity shortage or a refinery backlog.
Do not apply this persistent oil floor to Space Age lithium brine on Aquilo. That resource is finite; see Aquilo fluid intake stops for that separate case.
Sources and references
Questions and contributions
Submissions are currently paused. You cannot enter or send a post until reception resumes.