Research and construction
Scope: PC release 1.2, standard settings, no mods. Unlock Power Augmenter in MAM Alien Technology. If unavailable, complete prerequisite nodes and check research deliveries; collecting construction materials does not bypass research.
| Material for one building | Count |
|---|---|
| Somersloop | 10 |
| SAM Fluctuator | 50 |
| Cable | 100 |
| Encased Industrial Beam | 50 |
| Motor | 25 |
| Computer | 10 |
Research and wiring cost extra. Somersloops also serve production amplification: decide their allocation before committing the entire stock. Construction material is not continuously consumed fuel.
Add base output before applying the boost
For one unfueled augmenter, include its own 500 MW before adding 10%. With 5000 MW of existing generation: (5000 + 500) × 1.10 = 6050 MW.
Two unfueled buildings on that same grid give (5000 + 1000) × 1.20 = 7200 MW. Boost percentages add; do not multiply by 1.10 repeatedly. These examples assume existing generation continues, not that an augmenter restarts generators lacking fuel.
- Identify the grid containing the generators and factory to boost.
- Build and wire the augmenter into that grid.
- Check supply and boost on the power graph.
- Check for an isolated grid or an open switch separating the factory.
Stored energy is not generator output. Never add MWh of storage to MW in this calculation.
The belt input is for the larger boost
Supply 5 Alien Power Matrices per minute to raise that building’s boost from 10% to 30%. This is not 40%, and one delivery is not a permanent upgrade.
With the same 5000 MW and one steadily fueled building: 5500 × 1.30 = 7150 MW, or 1100 MW above its unfueled result. Compare that increase with the extra consumption of the matrix production chain; the whole factory may gain no headroom if the chain consumes more.
Matrices require separate late-game research and production. Until available, use the unfueled mode and verify wiring. Somersloops on the belt are not substitute fuel.
When figures differ
| Symptom | Check |
|---|---|
| Factory gains no headroom | Same grid, and existing generators actually running |
| 30% is not sustained | Continuous delivery of the correct 5/min fuel |
| Expected 21% from two | Two unfueled boosts add to 20%; include both 500 MW outputs |
| Less headroom after adding fuel production | Compare extra generation against chain consumption |
How storage differs · Separate grids and switches
Sources and references
Questions and contributions
Submissions are currently paused. You cannot enter or send a post until reception resumes.