A battery stores surplus power and discharges when generation on the same grid is not enough. It is not a replacement for a generator. First connect one battery under a roof and check whether grid excess and stored power increase.

Scope: PC version 1.6 series, base game, no DLC or mods. This example assumes Crashlanded and adds a battery to a grid with existing wood-fired generators. The developer’s version announcement is distinguished from collaboratively edited Wiki descriptions; in-game connection behavior and outage duration were not tested. Japanese UI labels may vary by translation, so check the English term and your current screen.

Research and materials for one battery

Battery research requires Electricity first. Check in the research screen whether it is already complete. Being able to use a generator and being able to build a battery are separate research conditions.

PreparationRequirement for one batteryWhat to check
Steel70Main battery construction material
Components2Steel alone is not enough
ResearchBattery after ElectricityCompletion in the current scenario
Power conduits and roofAdditional, based on placementGrid connection and protection from rain and snow
GenerationSurplus beyond consumption is requiredSource of power for charging

A newly built battery starts empty. If you use wood-fired generators, check materials, assigned workers, and fuel in Preparing power for a freezer. Keep the cost of the building separate from the cost of conduits and the surrounding structure.

Connect to the power conduit and check charging

These steps check one initial battery. One battery is not guaranteed to get you through the night or an outage.

  1. Check research, materials, and available construction workers; choose the grid connected to your generators.
  2. Prepare a roof over the battery location. Check that the roof is actually completed, not only designated for construction.
  3. Place and build the blueprint for one battery, adjacent to a conduit connected to an active power grid.
  4. Check generator fuel and operation, along with the consumption of other buildings on the same grid; ensure generation exceeds consumption.
  5. Advance time while checking Grid Excess/Stored and the battery’s stored power. If the charge does not increase, check the connection and surplus before building more batteries.

Buildings can auto-connect when they are close to a conduit; that does not mean a battery connects the same way. A battery must be adjacent to a conduit, a power source, or another battery. Do not assume it connects because you placed it near a Cooler.

Why it does not charge or empties quickly

StateCheck firstNext action
It does not appear in the build menuBattery researchCheck Electricity and its completion status
It is empty right after constructionInitial state and surplusConnect it and charge from surplus power
The generator runs but stored power does not increaseGrid connection and total consumptionCheck that it is on the same grid and surplus remains
Stored power decreasesDifference between generation and consumptionCheck for running out of fuel or increased load
Rain or snow causes an accidentRoof over the batteryLook for gaps in the actual roof

If consumption remains higher than generation, adding batteries does not provide a source of charge. Review unused building power or generation before estimating how much capacity you need. If the freezer stops, separate a power-grid issue from a room-temperature issue and check whether the food actually froze.

Stored-power units and what the roof does

One battery has a maximum capacity of 600 Wd; this is not the same unit as W. 1 Wd is the energy used by a 1 W device over 24 hours. Charging efficiency is 50%, so not all surplus generation is added to stored charge. Do not treat it as “a 600 W generator” while ignoring total grid consumption or losses.

A battery without a roof can cause a short circuit in rain or snow. A roof helps protect it, but does not guarantee immunity from every short circuit or fire on the grid. Check generation, connections, stored charge, and roofing separately. This guide does not recommend an optimal battery count, a guaranteed fire-proof wiring design, switching circuits, or DLC equipment.

If construction is stalled, see Work priorities; for food temperature, see Freezer checks!

If you switch to wind power, check Turbine clearance and output separately from battery shortage.

To increase daytime generation, see Solar generator research, roofing, connections, and nighttime shutdown!

If you receive a solar flare warning, see Freezer, room temperature, and defense checks during a power outage and distinguish it from ordinary low charge.

Sources and references

Questions and contributions

Share questions, corrections or play reports. Only approved posts for this article and language appear here.

Submit for review

Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.