Separate factory logistics from player movement
This guide covers the base game 2.0.77, normal quality, and Nauvis, and explains how to use the equipment in the player’s armor. It does not stop the belt itself; it prevents you from being carried along while standing on the belt.
| Goal | What to use or check |
|---|---|
| Stand still on a belt | Belt immunity equipment |
| Send items to the right place | Belt and inserter direction and placement |
| Walk faster | Other equipment, such as Exoskeletons |
| Increase available power | Power sources and Personal Batteries |
For stalled logistics, see basic checks for belts and inserters. Do not expect this equipment to fix a reversed inserter or missing ingredients.
Check the research and the ingredients for one unit
Find Belt immunity equipment in the research list. In 2.0.77, its direct prerequisite is Portable Solar Panel research. Once the research is complete, craft the finished equipment.
| Direct ingredients for 1 unit | Amount |
|---|---|
| Advanced Circuit | 5 |
| Steel Plate | 10 |
| Equipment produced | 1 |
This table lists only the direct ingredients, not the total expanded materials needed to make the Advanced Circuits. Keep having a regular transport belt in your inventory separate from having crafted the equipment that prevents belt movement.
It is also a good idea to check your power setup before collecting ingredients. If power is insufficient after crafting, the equipment may sit installed without working.
Put it in one cell of the grid you are wearing
With the default PC controls, right-click the armor to open the equipment grid. One unit takes up 1×1. Do not try to force it into armor without room for equipment.
- Check which armor you are currently wearing.
- Open its equipment grid.
- Put Belt immunity equipment in one empty cell.
- Check for a power source in the same grid.
- Check the battery’s remaining charge.
- On a belt in a safe area, check whether you are carried along.
For the test, choose a place away from enemies and trains. Compare the same belt before and after installing the equipment to make the effect easier to see. Also check that you are not testing equipment inside a different armor stored in your inventory.
It uses 100 kW even after you step off the belt
At normal quality, the equipment draws 100 kW continuously from the equipment grid. Do not calculate its use as if it only ran while you were on a belt. If the battery keeps draining after you step off, check this equipment’s power use.
One normal-quality Portable Solar Panel produces at most 30 kW during the day on Nauvis. Do not expect one panel to continuously supply 100 kW. Four panels reach a daytime peak of 120 kW, but that is not a nighttime or daily-average figure and does not guarantee the power needs of all your equipment.
| Figure to check | What it tells you |
|---|---|
| Equipment use: 100 kW | Rate of energy consumption |
| One solar panel: 30 kW peak | Comparison with maximum daytime generation |
| Battery charge | Energy stored right now |
| Battery capacity | Storage limit, not power generation |
Check day and night generation from Portable Solar Panels separately from Personal Battery charging. Adding empty batteries does not create power on the spot.
Separate whether you need it from why it stops working
When you are fixing layouts in a factory with many belts, being able to stand still in one place can make the work easier. If you do not need it on a trip away from the factory, consider removing it from the grid based on your needs. Confirm that the equipment moved back to your inventory and check the remaining power sources and batteries in the grid.
| Problem | What to review |
|---|---|
| Cannot craft it | Completed research and the direct ingredients |
| Still carried along after equipping | The armor you are wearing and its power supply |
| Charge drops with one solar panel | The gap between 30 kW peak and continuous 100 kW use |
| Charge drops after stepping off the belt | Continuous use and other equipment |
| Belt logistics still fail | Player movement and item logistics are separate issues |
Confirm the effect of one unit before deciding whether to use it for regular work. Do not add more equipment before you know what is causing the power shortage!
Sources and scope
The published Wube factorio-data for 2.0.77 was checked for direct ingredients, prerequisite research, 1×1 size, and 100 kW use. The official Factorio Wiki’s Belt immunity equipment entry was cross-checked for preventing belt movement and continuous power use even when not standing on a belt. The solar panel’s 30 kW figure uses the same conditions as the existing fixed-version guide. This covers base game, normal quality, and player equipment; vehicles, Space Age, quality differences, mods, all control setups, exact runtime, and in-game testing were not covered. Four panels’ 120 kW daytime peak is arithmetic; testing in a safe area and removing equipment based on need are editorial recommendations.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.