Tell battery ingredients apart from a Personal battery
The normal Personal battery research directly requires Battery and Portable Solar Panel equipment research. Select the equipment recipe after the research is complete.
| Direct materials for one normal unit | Required amount |
|---|---|
| Battery | 5 |
| Steel plate | 10 |
| Personal battery produced | 1 |
Having five Batteries is not the same as having one Personal battery. Distinguish the Battery ingredient, the Accumulator placed in a factory, and the Personal battery placed in armor by their item names and the finished equipment.
Do not substitute ingredients for another piece of equipment such as MK2. This guide covers the normal version, so the suggestion is to count just enough for one unit first.
Fit it into a 1×2 space and check the armor you are wearing
One normal Personal battery has a 1×2 footprint. Two empty slots that are not adjacent may not fit; check that there is a contiguous space. On the standard PC controls, right-click the armor to open the grid.
- Check the armor in your equipment slot.
- Right-click it to open the equipment grid.
- Place the Personal battery in a 1×2 space.
- Check for a power source in the same grid.
- With that armor equipped, check the charge display.
- Wait a little and note whether the charge increases, stays the same, or decreases.
Equipment remains in armor stored in your inventory, but it will not operate or charge/discharge if you are not wearing that armor. Check both the armor containing the battery and the one you are currently wearing. If you changed your controls, check the current input.
Provide a power source and check what other equipment is using
A battery stores power generated by a source in the equipment grid for later use. As a first source, see installing a Portable Solar Panel. On Nauvis, output varies by day and night, so check the same equipment during the day.
| Charge behavior | What to check next |
|---|---|
| Stays empty | Power source, whether you are wearing the armor, and time of day |
| Increases very slowly | Source output and what other equipment is using |
| Does not increase from full | Whether it has already reached capacity |
| Decreases when you start using equipment | Whether the equipment uses more power than the source generates |
| No change in another armor | Whether you are viewing the grid you are wearing |
Do not assume “not charging” has one cause. An empty battery and a full battery are different cases too. Rather than deciding from one look at the display, compare it with the time of day and whether work has started or stopped.
Separate 20 MJ of capacity from equipment power consumption
One normal-quality normal Personal battery has a capacity of 20 MJ. This is stored energy; it is not a power-generation rate of 20 MW.
| Number of normal units | Combined capacity |
|---|---|
| 1 | 20 MJ |
| 2 | 40 MJ |
| 3 | 60 MJ |
These are arithmetic totals for units of the same normal quality. Adding an empty battery does not give you a full charge's worth of power on the spot. Check the charge after increasing capacity too.
How many minutes it lasts at night or during work depends on charge, generation, and equipment used at the same time. Do not infer “it will run all night” from capacity alone. If you want longer operation, first determine whether the issue is the power source or consumption before increasing capacity.
Compare before and after a trip or when equipment stops
For your first test, check charge in a safe place before starting work. If a Personal roboport does not operate, check robots and construction materials as well as power. Adding batteries alone does not solve missing materials.
For an Exoskeleton, check power and its toggle state separately. Even if charge remains, check the equipment itself; do not replace everything before identifying the cause.
Check in this order: finished item, grid in the armor you are wearing, power source, charge, and equipment in use. Start with one battery and compare the charge before and after setting out!
Sources and scope
Wube's public factorio-data for 2.0.77 was used to check the normal recipe of 5 Batteries and 10 Steel plates, research prerequisites, 1×2 footprint, and 20 MJ capacity. The official Factorio Wiki's Personal battery and Equipment modules pages were cross-checked for the role of storage equipment, right-click controls, and operation and charging/discharging while worn. Scope is the base game, normal quality, and normal Personal battery; daytime checks assume Nauvis. Testing one unit and comparing charge before and after are editorial suggestions. MK2/MK3, quality differences, mods, every equipment combination, exact charging time, nighttime duration, and in-game operation were not tested.
If you want to change nighttime visibility, see installing Night vision and checking power at night to distinguish daytime generation from nighttime use.
Sources and references
Questions and contributions
Share questions, corrections or play reports. Only approved posts for this article and language appear here.
Submit for review
Do not include personal details, passwords or private information about others. Text only. Publication and replies are not guaranteed.